  1. Bit tips for breakers - Electrician Talk

    Feb 24, 2018 · A square d QO breaker 10-30amps is supposed to be torqued to 36in-lbs and 35-70amps is 45 in-lbs. Its a lot less then you think.

  2. What are rules for double-tapping breakers | Information by …

    Sep 26, 2005 · 1. Square D is the only manufacturer that designs breakers to support 2 wire connections. 2. The rated load from both circuits cannot exceed 80% of the breaker rating. 3. …

  3. Type xo breakers | Information by Electrical Professionals for ...

    Nov 29, 2010 · I looked at a panel that had Square D type XO Circuit Breakers. The panel was a mess, missing cover, and busbar looked corroded. I need some more ammo to help get the …

  4. Tandem breakers no longer acceptable for residential-Just …

    Apr 27, 2015 · I recently had a final inspection performed on a renovation. The electrical inspector is a third party inspector and not one of the township itself. In the renovation we used an …

  5. How many circuit breakers in Square D panel | Information by …

    Jul 15, 2013 · My question is: does Square D do it the same way? Yes. The tandem breakers with out the rejection tab, are only for use in panels built before UL had a CTL provision, roughly …

  6. Square D breakers in a Siemans panel? | Information by Electrical ...

    Jul 10, 2009 · Can Square D circuit breakers be used as replacement breakers in a Siemans residential service panel? What brand is allowed in a Siemans? Where can I find listings of …

  7. Help With Square D Breaker | Information by Electrical …

    Jul 6, 2015 · For any of you guys who use Square D breakers a lot, I need some help with a couple of breakers. What is the difference between these two breakers? EDB14020 …

  8. Square D breakers in GE panel - Mike Holt's Forum

    Aug 9, 2017 · I know that only breakers recommended by the panel manufacturer should be used. I just discovered the electrician who added c. 20 breakers (new circuits) to my GE panel used …

  9. Interchangable breaker list - Electrician Talk

    Feb 10, 2014 · Mike: Seems you had a wide variety of comments. Most seemed to indicate that the practice of installing something that the panelboard manufacturers label clearly prohibits …

  10. Square D Dual Function Breakers are randomly tripping on …

    Nov 4, 2017 · I am troubleshooting a new, permitted, complete rewire job that includes a new 200 amp Square D Home panel as of 2016 and has been in service with no problems until …